Defining the address space

Discovery starts with defining the address blocks to be scanned. For each block defined in CIDR notation, the total address count, the addresses seen as active, and the utilization rate are tracked.

Utilization rate is not just a statistic: when the address space starts filling up, adding a new device causes unexpected problems, and this is usually noticed at the worst possible time.

Candidates and confidence score

Addresses that respond during a scan are not written directly into the inventory; they are listed as candidates. Each candidate carries a device-type guess based on its open ports, along with a confidence percentage showing how clear the underlying signal is.

A low confidence score is not an error; it says the information is insufficient. In that case, the operator decides after gathering more information.

Why does the approval step stay with the operator?

Automatic inventory would quietly let misclassified devices into the system and gradually make the monitoring picture unreliable. That is why discovery candidates remain in a 'pending' state and are only added to inventory once approved.

An approved device is grouped by type and category; incidents are then linked to these records, making it visible which location is affected.

Private networks and the local connectivity component

On networks closed off from the internet, resources cannot be queried directly from the outside. In this case, a collector component is installed inside the network and it runs the checks.

The requirements and duration of this step depend entirely on your environment; no installation timeline is promised without verifying access permissions and network rules.

Related terms

FAQ

Does discovery harm the network?

Scan scheduling and scope are configurable. When heavy scans run at planned intervals, the load stays under control.

What happens if the device-type guess is wrong?

A candidate does not enter inventory without approval; the operator can correct the type or reject the candidate.

Demo request

Get in touch

Tell us about your environment and the targets you want to monitor; let's work out the right setup method and pricing together.

A monitoring plan that fits your needs

  1. 01Number of targets to monitor
  2. 02Check types and frequency
  3. 03Usage needs

Email: sales@mintyfi.com

Leave your details

We use cookies for visit statistics. Cookie policy